Description
Instek GLC-9000 – Leakage Current Tester
Touch Panel with Color LCD Display
9 Different Measurement Network to Simulate the Resistance of Human Body
8 Different Types of Leakage current for Medical & General Electrical Equipment
Various Leakage Current Measuring Mode: DC/AC/AC+DC/AC Peak
Upper & Lower Limitation for PASS/FAIL Judgment
The GLC-9000 complies with IEC, UL, and other international electrical safety standards requiring leakage current measurement. Leakage current tests can be separated into 3 basic types:
Earth Leakage current
Enclosure Leakage current
Patient Leakage current
Leakage Current Tester: Testing is Just a Fingertip Away
The GLC-9000, leakage current tester, is used to perform leakage current (or called touch current) tests on medical electrical (IEC 60601-1) and general-purpose electric & electronic (IEC 60990) equipment. This tester engages with nine measurement networks (or called Measuring Device) to provide the simulation of the human body while the EUT (equipment under test) is taking a leakage current testing in compliance with the specific standards or regulations such as IEC, UL, JIS…etc.
In order to provide a simple operation environment, the GLC-9000 equips with a large TFT LCD touch panel to configure the system as well as to present the measurement settings information and result simultaneously. Besides, there are 50 preset testing conditions, which conform to IEC60990 and other standards, for general electric equipment can be recalled to reduce the setting time. In addition, 30 sets of empty memory are available for user-defined settings.
A Meter mode is also available for the GLC-9000, it uses the measurement terminal (T1/T2) to measure the voltage in the same way of the ordinary voltmeter. During the voltage measurement, the SELV function (safety extra-low voltage) is applicable to detect whether the voltage value between measuring points exceeds the SELV setting.
Simple and Intuitive System
The color TFT touch screen makes operation intuitive and simple and also makes it easier to observe test result.
Various Measurement Network
Nine Measurement Network are available for measuring the leakage current of electrical and medical equipment.
Preset Test Conditions
50 preset test conditions conforming to IEC 60990 for general electric equipment. Additional 30 sets empty memory for user defined setting.
Various Standard Interfaces
The various practical interfaces are equipped as standard accessory, making control convenient and flexible.
Measurement Network (MD)
Note:The standard number is only listed as example
Note:The networks listed can be used with all applicable standards
Reviews
There are no reviews yet.